M
维修案例
aintenance case
客户名称 :东莞市XX公司
现象 :磁带机开机自检 清洁灯亮
磁带机磁头参数检测:MR Resistance - data readers 正常值为55
Open Head Cable test failed
CHN_AFE2_Set_Bias_Currents(REV order 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.5)
CHN_AFE2_Set_Servo_Bias_Currents(REV order 10.5 10.5)
[1] Calibrate last=9763, cur=13883, next=15595880
MR Resistance - data readers
FWD:
57.5 60.6 58.5 58.9 58.1 55.7 57.2 58.5 57.7 56.0 55.2 56.0 55.0 55.6 54.7 54.7
BKWD:
53.4 52.6 52.6 52.0 52.4 52.9 54.7 56.4 56.1 55.1 55.1 56.5 56.5 56.8 57.2 56.2
MR Resistance - servo readers
FWD:
61.7 60.2
BKWD:
57.1 60.6
CHN: Timestamp = 14.563534849
CHN: CHN_AFE2_Setup(Cmd = 9 [Gen3] [Vel1] [dir = 0])
RAS: MR resistance is without range
维修 :磁头损坏 需要更换磁头
维修结果 :磁头更换后磁带机正常
注:因涉及到客户个人隐私,客户的部分信息我们将进行屏蔽处理.